This version adds web plate support in bolted column splice connections and related calculation updates.

Also in this version:

  • Fixed issues with bolt tension capacity
  • Fixed issues with beam web block shear check when a brace is nearby
  • Fixed issues where beam axial force was not correct with a brace nearby
  • Fixed missing weld check in gusset to column connections
  • Fixed issues where moment in gusset to column may not be correct
  • Report no longer uses doubler weld size when the doubler is not designed
  • Fixed issues with coped beam web strength check for AISC 15th edition

To update, open Descon and click Approve when the prompt appears.
If you do not get a prompt, go to the Support tab and click Update.