This version adds seated shear connections, bolted and welded. Seated connections to HSS columns are welded only.

Also in this version:

  • Removed the stiffener screen
  • Updated the report for seated connections
  • Fixed issues where the calculations for column web doubler were incorrect
  • Fixed a crash when loading a file designed with AISC 15th edition
  • Fixed issues with HSS column wall flexural yielding calculations
  • Fixed issues with gusset plate bearing calculations
  • Fixed missing headers in the Materials and Welds dialog